Visual Feedback Message Definitions for E-Plex 2000 Series and PowerPlex 2000 Series

Condition Parameters
  Green LED Red LED Duration Rate
Valid pushbutton pressed ON OFF 1/10 sec Once
Timeout expired OFF ON 1 sec; A Once
Valid access 
code keyed
ON OFF 1 sec Once
Access granted ON OFF 1/10 sec 1 sec

Access granted 

(battery low condition)

ON ON 1/10 sec 1 sec
Access denied OFF ON 1 sec; A Once; B
Valid programming 
entry
ON OFF 1 sec Once
Invalid programming entry (including duplicate access code OFF ON 1 sec; A Once; B
Tamper shutdown beginning OFF ON 2 sec Once
Tamper shutdown state OFF ON 1 sec; C 10 sec
Tamper shutdown ending ON OFF 2 sec; C Once
For PowerPlex 2000 only:
Lock is ready when front lever is depressed ON OFF 1/10 sec Once
Lock's stored power is 
started to fade
OFF ON 1/10 sec 1 sec

Legend

A = 1/10 second.

B = Twice.