Summary of Pushbutton Programming Commands for E-Plex 2000 Series and PowerPlex 2000 Series

Updated May 8, 2026

Configure

Command Description of Command
000 # 
MMMMMMMM# MMMMMMMM#
‘Modify Master User Access Code (lock’s activation)’ (Always 8 digits)

004 # 

TT#

‘Unlock time setup’ (TT = 02 to 20 seconds)

005 # 

TT#

‘Passage Mode Timeout setup’ (TT = 01 to 24 hours - duration time in hours; 00 = no time limit) Note: Not applicable to PowerPlex 2000 models

006 #

TT#

‘Tamper time setup’ (TT = 00 to 90 seconds)
007 # 

TT#
‘Tamper wrong try setup’ (TT = 03 to 09)

008 # 

VV#

‘Buzzer volume control’ (VV = 00 to 03; 00 = off; 01 = Low; 02 = Normal; 03 = High)

009 # 

LL#

‘Modify access length’ (LL = 04 to 08 digits)
099 # ‘Reset to factory default values’, except access code length. (Master, manager and access user are retained if already programmed.)

Activate Users

Command Description of Command

300 # 

NNN#

‘Activate User Access Code’ 

NNN = specific User ID location (001 to 099)

301 # 

NNN#

‘Activate Manager Access Code’ 

NNN = specific User ID location (001 to 099)

302 # 

NNN#

‘Activate Service User Access Code’ 

NNN = specific User ID location (001 to 099)

398 # ‘Activate all User Codes’ (except Master and Manager)

399 # 

P#

‘Activate / De-Activate Passage Mode’ (P = 0 or 1; 0 = disable Passage Mode; 1 = enable Passage Mode)

400 # 

NNN#

‘De-Activate User Access Code’ 
 

NNN = specific User ID location (001 to 099)

401 # 

NNN#

‘De-Activate Manager Access Code’ 

NNN = specific User ID location (001 to 099)

402 # 

NNN#

‘De-Activate Service User Access Code’ 

NNN = specific User ID location (001 to 099)

498 # ‘De-Activate all User Codes’ (except Master and Manager)

499 # 

L#

‘Activate / De-Activate Lockout Mode’ (Master User is not affected by Lockout Mode) (L = 0 or 1; 0 = disable Lockout Mode; 1 = enable Lockout Mode)

Add/Modify Users

Command Description of Command
100 # 
NNN # 
UUUU {UUUU}# 
UUUU {UUUU}#
‘Add/Modify User Access Code’ NNN = specific User ID location (001 to 099) (Combination length can be 4 to 8 digits, depending on access length LL setting)
101 # 
NNN # 
UUUU {UUUU}# 
UUUU {UUUU}#
‘Add/Modify Manager Access Code’ NNN = specific User ID location (001 to 099) (Combination length can be 4 to 8 digits, depending on access length LL setting)
102 # 
NNN # 
UUUU {UUUU}# 
UUUU {UUUU}# 
HH#
‘Add/Modify Service User Access Code’ NNN = specific User ID location (001 to 099) (HH = 01 to 24 hours - duration time in hours; 00 = onetime entry; Combination length can be 4 to 8 digits, depending on access length LL setting)

Delete Users

Command Description of Command

200 # 

NNN#

'Delete User Access Code’

201 # 

NNN#

‘Delete Manager Access Code'

202 #

NNN#

‘Delete Service User Access Code’
299 # ‘Delete all User Access Codes’ (except Master and Manager)

Diagnostic

Command Description of Command

500 # 

123456789*0#

‘Manual diagnostic’