Configure
| Command | Description of Command |
| 000 # MMMMMMMM# MMMMMMMM# |
‘Modify Master User Access Code (lock’s activation)’ (Always 8 digits) |
|
004 # TT# |
‘Unlock time setup’ (TT = 02 to 20 seconds) |
|
005 # TT# |
‘Passage Mode Timeout setup’ (TT = 01 to 24 hours - duration time in hours; 00 = no time limit) Note: Not applicable to PowerPlex 2000 models |
|
006 # TT# |
‘Tamper time setup’ (TT = 00 to 90 seconds) |
| 007 # TT# |
‘Tamper wrong try setup’ (TT = 03 to 09) |
|
008 # VV# |
‘Buzzer volume control’ (VV = 00 to 03; 00 = off; 01 = Low; 02 = Normal; 03 = High) |
|
009 # LL# |
‘Modify access length’ (LL = 04 to 08 digits) |
| 099 # | ‘Reset to factory default values’, except access code length. (Master, manager and access user are retained if already programmed.) |
Activate Users
| Command | Description of Command |
|
300 # NNN# |
‘Activate User Access Code’ NNN = specific User ID location (001 to 099) |
|
301 # NNN# |
‘Activate Manager Access Code’ NNN = specific User ID location (001 to 099) |
|
302 # NNN# |
‘Activate Service User Access Code’ NNN = specific User ID location (001 to 099) |
| 398 # | ‘Activate all User Codes’ (except Master and Manager) |
|
399 # P# |
‘Activate / De-Activate Passage Mode’ (P = 0 or 1; 0 = disable Passage Mode; 1 = enable Passage Mode) |
|
400 # NNN# |
‘De-Activate User Access Code’ NNN = specific User ID location (001 to 099) |
|
401 # NNN# |
‘De-Activate Manager Access Code’ NNN = specific User ID location (001 to 099) |
|
402 # NNN# |
‘De-Activate Service User Access Code’ NNN = specific User ID location (001 to 099) |
| 498 # | ‘De-Activate all User Codes’ (except Master and Manager) |
|
499 # L# |
‘Activate / De-Activate Lockout Mode’ (Master User is not affected by Lockout Mode) (L = 0 or 1; 0 = disable Lockout Mode; 1 = enable Lockout Mode) |
Add/Modify Users
| Command | Description of Command |
| 100 # NNN # UUUU {UUUU}# UUUU {UUUU}# |
‘Add/Modify User Access Code’ NNN = specific User ID location (001 to 099) (Combination length can be 4 to 8 digits, depending on access length LL setting) |
| 101 # NNN # UUUU {UUUU}# UUUU {UUUU}# |
‘Add/Modify Manager Access Code’ NNN = specific User ID location (001 to 099) (Combination length can be 4 to 8 digits, depending on access length LL setting) |
| 102 # NNN # UUUU {UUUU}# UUUU {UUUU}# HH# |
‘Add/Modify Service User Access Code’ NNN = specific User ID location (001 to 099) (HH = 01 to 24 hours - duration time in hours; 00 = onetime entry; Combination length can be 4 to 8 digits, depending on access length LL setting) |
Delete Users
| Command | Description of Command |
|
200 # NNN# |
'Delete User Access Code’ |
|
201 # NNN# |
‘Delete Manager Access Code' |
|
202 # NNN# |
‘Delete Service User Access Code’ |
| 299 # | ‘Delete all User Access Codes’ (except Master and Manager) |
Diagnostic
| Command | Description of Command |
|
500 # 123456789*0# |
‘Manual diagnostic’ |