What are the recommended sequence of operations for start-up programming in E-Plex 30xx/50xx?

Updated Feb 17, 2026

Resolution

If the E-Plex is in factory mode.

  • Program the Access Code Length (default length is four digits).
    The access code field length can only be changed when the lock is not activated (when still in the factory mode).
  • Change factory Master to your own Master Code (always eight digits) to place lock in access mode.

Steps to put lock in Pushbutton Programming Mode

  1. Set the Date / Time
  2. Program the Lock ID and Unlock time
  3. Program the Lock for the Duration of Passage Mode (if desired).
  4. Program the Lock for Tamper Time Settings.
  5. Program the Lock for Buzzer Volume.
  6. Add Access Codes as desired.

Default values of the E-Plex® Lock programmable parameters

Parameters Factory Default Values
Date (MM/DD/YY) 01/01/00
Time (HH:MM) 00:00
   
Lock state Unprogrammed
Lock ID 0000
Passage mode open time limit 9 hours
Passage mode Disabled
Lockout mode Disabled
Unlock time 2 seconds
Buzzer volume control Low
Tamper shutdown time 30 seconds
Tamper attempt count 4 attempts
Access code length 4 digits
Latch Holdback Mode Disabled (E-30xx only)
Swingbolt Privilege Disabled (E-30xx only)
Privacy Privilege Disabled (E-50xx only)
   
Master combination 12345678 (8 digits)
   
Access code None
Code status Activated
M-Unit user’s combination None
M-Unit user’s status Disabled

Applies To

E-Plex 30xx/50xx Series Locks