User - General Information in E-Plex 36xx/37xx/56xx/57xx Series Locks

Updated Feb 17, 2026

User - General Information in E-Plex 36xx/37xx/56xx/57xx Series Locks

Master and Manager users can unlock the door or enter programming mode, with strict timing limits and error recovery handled by the * key, while all users are stored in a 300-slot memory table with the Master reserved in slot 000.

Master and Manager credentials have two functions:

  1. Unlock the door by entering the access credential normally (do not include #).

  2. Enter LearnLok™ Pushbutton Programming Mode by entering #, then the access credential, then # again.

User storage:

  • Each user (Master, Manager, or Access user) occupies one memory slot in the lock’s user table.

  • The lock supports 300 user slots, numbered 001–300.

  • The Master user is stored in location 000, which is reserved exclusively for the Master.

Programming time limits (Master and Manager only):

  • You have 15 seconds total to complete an entire programming sequence.

  • You may not pause more than 5 seconds between individual button presses.

  • If either time limit is exceeded, the lock will:

    • Abort the current programming sequence

    • Exit programming mode automatically

    • Provide a Keypad Timeout notification using LEDs and the buzzer

Error correction:

  • If you make an incorrect entry during a programming sequence, press the * key.

  • Pressing * clears all input from the start of the current command.

  • The 15-second timer resets, allowing you to re-enter the full command sequence.