User - General Information in E-Plex 36xx/37xx/56xx/57xx Series Locks
Master and Manager users can unlock the door or enter programming mode, with strict timing limits and error recovery handled by the * key, while all users are stored in a 300-slot memory table with the Master reserved in slot 000.
Master and Manager credentials have two functions:
Unlock the door by entering the access credential normally (do not include
#).Enter LearnLok™ Pushbutton Programming Mode by entering
#, then the access credential, then#again.
User storage:
Each user (Master, Manager, or Access user) occupies one memory slot in the lock’s user table.
The lock supports 300 user slots, numbered 001–300.
The Master user is stored in location 000, which is reserved exclusively for the Master.
Programming time limits (Master and Manager only):
You have 15 seconds total to complete an entire programming sequence.
You may not pause more than 5 seconds between individual button presses.
If either time limit is exceeded, the lock will:
Abort the current programming sequence
Exit programming mode automatically
Provide a Keypad Timeout notification using LEDs and the buzzer
Error correction:
If you make an incorrect entry during a programming sequence, press the
*key.Pressing
*clears all input from the start of the current command.The 15-second timer resets, allowing you to re-enter the full command sequence.