User Credentials in E-Plex 36xx/37xx/56xx/57xx Series Locks

Updated Feb 17, 2026

User Credentials in E-Plex 36xx/37xx/56xx/57xx Series Locks

Each time you add a user to give access to a door, you must program the lock at the keypad with an Access Credential for this user who may be a manager user and/or an Access user and/or a Service user. 
This user access credential can be either card only, or PIN followed by card for Manager and regular 
Access users; and can be PIN only the Service users. 
The global Master user’s access will always be an 8-digit PIN only. 
You can also easily delete the access credential for an existing user right at the lock keypad.

Credential to Access the Lock: 

Credential  Access Credential
Master User PIN only access - no expiry 
Manager User Card only access
PIN & card access - no expiry 
 Access User Card only access;
PIN & card access - no expiry 
Service User PIN only access - no expiry
PIN only access - 1 through 96 hours access
PIN only access - one time entry only (“one shot”) 

Credential to Program the Lock: 

Credential  Access Credential
Master User #Master PIN# complete command code sequence ##
Manager User Card only mode # present card (green LED flashes) complete command code sequence ## 
In PIN & Card mode  # PIN # present card (green LED flashes) complete command code sequence ##

Important: User PINs that will be used in PIN & card access mode must not have the exact same digits in the same position as the Master PIN. 
The Master Code 00004992 is used as an example in the table below.