YD30D Double Sideload Lock Wiring

Updated May 13, 2026

Wiring Guide


The SL30DBL is supplied with a 7-way wire loom that plugs directly into the lock. The wires are color coded
as per table below, with the power and control wires being essential connections and the four monitor
connections being optional.

Wire Color Meaning Description
RED Power Supply
(12 - 24VDC)
Positive connection to DC power supply, “”
BLACK Negative connection to DC power supply, “”
BLUE Control Switched positive control input
VIOLET Bolt Position
Monitor
Normally open contact (NO), closed when the bolt pin is extended (optional)
VIOLET
WHITE Door Position Monitor Normally open contact (NO), closed when the strike is aligned with the lock (optional)
WHITE

Fail Safe Connection

Fail Safe connection wiring diagram for SL30DBL

When in Fail Safe configuration, applying positive voltage to the control wire triggers the SL30DBL to lock
(active-high locking signal). In the event of a power cut, the SL30DBL will unlock.

Fail Secure Connection

Fail Secure connection wiring diagram for SL30DBL

When in Fail Secure configuration, applying positive voltage to the control wire triggers the SL30DBL to unlock
(active-low locking signal). In the event of a power cut, the SL30DBL will remain locked.