YD30D Double Sideload Lock Technical Data and Pre-Installation Assessment

Updated May 13, 2026

Technical Data Dimensions Pre-Installation Assessment   Wiring Assessment

Technical Data

Materials
Bolt Stainless Steel 17-4PH
Mechanical 
Bolt Extension 13mm
Door Gap max. 6 mm(1/4")
Misalignment Correction max. 8mm (5/16 inch)
Cycle Life 1,000,000 cycles
Holding Force 10,000N (2,250 lbf) (factory tested only)
Side Load Release 6,000N (1,350 lbf) (factory tested only)
Locking Time 1.0 seconds (typical)
Unlocking Time 0.3 seconds (typical)
Environmental
Operating Temperature -10°C to +55°C
Electrical
Power Requirements 12-24 VDC ±15%
Initial Power Up Time 11 seconds
Initial Current Draw 750mA@12VDC, 400mA@24VDC
Standby Current 40mA@12VDC, 25mA@24VDC
Signal Contacts Bolt Position (NO) 30VDC max., 100 mA max.
Door Position (NO)
Compliance
CE, UKCA, UL, FCC, IC, RCM, RoHS 2


Lock Dimensions

The dimensions shown are approximate and subject to change without prior notice.

Diagram showing lock dimensions.
Diagram showing lock dimensions (alternate view).

Housing Dimensions (Available Separately)

The dimensions shown are approximate and subject to change without prior notice.

Diagram showing housing dimensions (available separately).
Diagram showing housing dimensions (alternate view; available separately).

Dress Plate Dimensions (Available Separately)

Fitting Tab Dimensions (Available Separately)

The dimensions shown are approximate and subject to change without prior notice.

Diagram showing fitting tab dimensions (available separately).

Pre-Installation Assessment

Mounting Assessment

The first decision regarding installation is whether the SL30DBL will be mortised or surface-mounted. Mortise installation ensures a discreet solution as the lock and strike plate can be embedded into the door leaf and frame; however, in some instances, this is not possible. Glass doors, for example, require surface mounting, which is done with the aid of the SL30DBL housing and dress plate (available separately).

Diagram showing mounting options for mortised or surface mounting.

The lock and strike plate can be installed mortised (1), surface mounted (2), or a combination of the two (3). Regardless of the installation method it is vital that the lock face plate and strike plate are aligned vertically to each other and that the gap between them does not exceed 6mm (1/4 inch) when the door is closed.

When the door is closed, the resting position of the door leaf can be misaligned up to 8mm (5/16 inch) in either direction and the SL30DBL will pull the door into alignment with ease. This misalignment could be caused by an automatic door closer not aligning the door or natural distortions in the door assembly.

The SL30DBL can be installed vertically or horizontally but is not designed to be mounted in a floor cavity firing upwards or in a wet environment. Must be installed vertically for UL10C applications.

Wiring Assessment

Before installation begins, consideration must be made for where to run the wires and decide on what feedback is required from the lock. There are a total of seven available connections; three are compulsory power/control connections whilst the remaining four provide optional door and bolt position feedback. These optional connections can be integrated into access control or alarm systems to provide full monitoring. 

The correct gauge of wire needs to be chosen as voltage drop across the power/control wires can limit the locks operation. For all the remaining connections, a lower gauge wire can be used as these are only signal wires. The following table shows the maximum distance that the wire runs can be between the power supply and the lock, assuming the power supply outputs 12VDC or 24VDC.

Conductor Cross Sectional Area Maximum Distance
#AWG (mm²) at 12VDC at 24VDC
24 0.20 10m (33ft) 30m (98ft)
22 0.33 16m (52ft) 48 (157ft)
20 0.52 26m (85ft) 77m (253ft)
18 0.82 41m (135ft) 122m (400ft)
16 1.31 65m (213ft) 195m (640ft)
14 2.08 103m (338ft) 310m (1017ft)

Operating Mode Assessment

The SL30DBL can be set to one of two operating modes before installation: Fail Safe or Fail Secure.

When the operating mode is set to Fail Safe, supply voltage is applied to the control input to lock the door, and the SL30DBL will unlock in the event of power loss.

When the operating mode is set to Fail Secure, supply voltage is applied to the control input to unlock the door, and the SL30DBL will lock or remain locked in the event of power loss.

The failure mode of the SL30DBL is factory set as Fail Safe. Before the lock is installed this can be changed to Fail Secure by repositioning the switch located at the end of the product.