Description

A Manager user’s credential should be re-activated if it had been de-activated earlier - the procedure is very similar to the above procedure of activating an Access user.

Resolution

Required User Level: Master

  1. Put the lock into “LearnLokTM” Pushbutton Programming Mode.
  2. Enter Command 301# to re-activate a Manager user’s credential; you do not need this person’s PIN and/or card to do this.
  3. Enter this user’s ID location (001 through 300); we will use the ID location 015 in this example. 
    Enter a last # to indicate the end of programming. 
    Example of Complete Entry for user ID=015: 
    301#015# #. 
    You have now activated this Manager user’s credential which was temporarily de-activated.

Applies To

E-Plex 36xx, 37xx, 56xx, 57xx Series Locks