Activating Service User Credentials: E-Plex 36xx/37xx/56xx/57xx Series Locks

Updated Feb 16, 2026

Activating Service User Credentials: E-Plex 36xx/37xx/56xx/57xx Series Locks

Description

A Service user’s credential (PIN) should be re-activated if it had been de-activated earlier - the procedure is very similar to the above procedure of activating an Manager or Access user.

Resolution

Required User Level: Master

  1. Put the lock into “LearnLokTM” Pushbutton Programming Mode - # Master PIN (or Manager credential) #
  2. Enter Command 302# to re-activate a Service user’s credential; you do not need this person’s PIN and/or card to do this.
  3. Enter this user’s ID location (001 through 300); we will use the ID location 125 in this example.
    Enter a last # to indicate the end of programming. 
    Example of Complete Entry for user ID=125:
    302#125# #.
    You have now activated this Service user’s credential which was temporarily de-activated.

Applies To

E-Plex 36xx, 37xx, 56xx, 57xx Series Locks