Activating/De-Activating Passage Mode: E-Plex 36xx/37xx/56xx/57xx Series Locks

Updated Feb 16, 2026

Activating/De-Activating Passage Mode: E-Plex 36xx/37xx/56xx/57xx Series Locks

This guide explains how to enable or disable Passage Mode, which allows a door to remain unlocked for a programmed duration (1–24 hours). The lock automatically re-locks after the set time, regardless of any intermediate activations.

Description

Before activating Passage Mode, a default duration should be programmed for the door as per Procedure 12B: Program the Duration of the Passage Mode Period. 
Passage Mode enables free entry without a credential during the programmed duration.

Example: If the passage duration is set to 6 hours and you activate Passage Mode at 1:00, the door will automatically re-lock at 7:00. The lock can be taken in and out of Passage Mode multiple times during the 6-hour period, but it will always re-lock after the original programmed time. This ensures the lock never remains in free Passage Mode beyond the intended duration (1–24 hours).

Resolution

Required User Level: Master

  1. Put the lock into “LearnLok™” Pushbutton Programming Mode: # Master PIN (or Manager credential) #
  2. Enter command 399# to control Passage Mode.
  3. Enter 1# to activate or 0# to de-activate Passage Mode.
  4. Example to activate Passage Mode: 399#1# #
  5. Example to deactivate Passage Mode while still active: 399#0# #

Applies To

E-Plex 36xx, 37xx, 56xx, 57xx Series Locks