How to deactivate service user credentials in E-Plex 36xx/37xx/56xx/57xx Series Locks?

Updated Feb 16, 2026

How to deactivate service user credentials in E-Plex 36xx/37xx/56xx/57xx Series Locks?

This article explains how to temporarily deactivate a Service User’s credential on supported E-Plex lock models.
Deactivation is useful when a user is temporarily absent, such as during vacation, and allows for easy reactivation later.

Description

A Service User’s credential, if it has not expired, can be deactivated rather than deleted  as described in Procedure 10B.
This allows the credential to be reactivated later without reprogramming a new PIN or card.
This approach is recommended for temporary access suspension.

Resolution

Required User Level: Master, Manager

  1. Put the lock into “LearnLokTM” Pushbutton Programming Mode - # Master PIN (or Manager credential) #
  2. Enter Command 402# to de-activate a Manager user’s credential; you do not need this person’s PIN and/or card to do this.
  3. Enter this user’s ID location (001 through 300); we will use the ID location 125 in this example. 
    Enter a last # to indicate the end of programming. 
    Example of Complete Entry for user ID=125: 
    402#125# #. 
    You have now temporarily de-activated this Service user’s credential (PIN).

Applies To