This guide explains how to enable or disable global Lockout Mode, which temporarily disables all regular and manager user access codes (excluding the Master Code) during events like strikes or emergencies.

Description

The Master user (and only the Master) can perform a global lockout if required, for example during a strike or fire, etc. At times like this you do not want anyone to return to work and so you should perform a global lockout temporarily. The following procedure can either de-activate & re-activate all user credentials including the managers (but not the Master user) temporarily.

Resolution

Required User Level: Master, Manager

  1. Put the lock into “LearnLokTM” Pushbutton Programming Mode - ># Master PIN #
  2. Enter Command 499# to de-activate all users.
  3. Enter 1# to activate the Global Lockout Mode (or, 0# to de-activate Lockout Mode).
  4. Example of Complete Entry to activate Lockout Mode: 499#1# #.
  5. Example of Complete Entry to de-activate Lockout Mode if Lockout was still in effect: 499#0# #.

Applies To

E-Plex 36xx, 37xx, 56xx, 57xx Series Locks