Resolution
User does not know the Master Code:
-
Insert Mechanical Override Key
- Insert the key and turn counterclockwise, holding the lock open (cylindrical latch retracted).
- Within 5 seconds, press the # key and release the key.
-
Enter Reset Sequence State
- Press the # key and release the reset button within 5 seconds.
- If 5 seconds pass without pressing #, the lock resumes normal operation.
- When # is pressed, the lock exits the current state and flashes Green and Red LEDs alternately once per second.
- If any other key is pressed or timeout occurs after #, the lock exits the sequence and stays in access state.
-
Wait for 20-Second Master Code Window
- The lock provides a 20-second window for entering the Master Code.
- Do not enter anything if the Master Code is unknown. The “Reset Sequence In Progress” LED message will display.
-
Complete Reset After 15-Minute Wait
- After 20 seconds, the lock starts a 15-minute wait period. All key presses are ignored, and Green and Red LEDs blink once per minute.
- After 15 minutes, the “Reset Sequence In Progress” message appears for 20 seconds.
- Enter the sequence 1-2-3-4-5-6-7-8-# to reset the lock.
- If the sequence is not entered correctly, the lock aborts the reset and resumes normal operation.
|