Description
This procedure allows a user with the Master Code to perform a hard reset on an E-Plex 5xxx lock. Insert the mechanical override key, press the # key, and release the reset button to enter Reset Sequence State. The lock provides a 20-second window to enter the Master Code. If entered correctly, the lock resets to its unprogrammed state. Incorrect attempts decrement the Tamper Count. After four failed attempts, the lock enters a 30-second Tamper Shutdown.
|
Resolution
User knows the Master Code:
-
Insert Mechanical Override Key
- Insert the key and turn counterclockwise, holding the lock in the open position (cylindrical latch retracted).
- Within 5 seconds, press the # key and release the key.
-
Enter Reset Sequence State
- Press the # key and release the reset button within 5 seconds.
- If 5 seconds pass without pressing #, the lock resumes normal operation.
Pressing # enters Reset Sequence State, indicated by alternating flashing Green and Red LEDs every second.
- If any other key is pressed or timeout occurs after #, the lock exits the sequence and returns to access state.
-
Enter Master Code
- Users have 20 seconds to enter the correct Master Code.
- If correct, the lock performs a hard reset and returns to unprogrammed state.
- If incorrect, the Tamper Count decreases. After four failed attempts, the lock enters a 30-second Tamper Shutdown, then resumes normal operations.
- If no Master Code is entered during the 20-second window, the lock assumes the Master Code is unknown and begins a 15-minute wait period.
|