Summary of Pushbutton Programming Commands for E-Plex 5200/320xx Series
| Name | Command | Description of Command | Authorization |
| Configure | 000 # MMMMMMMM# MMMMMMMM# |
‘Modify Master User Access Code (lock’s activation)’ (Always 8 digits) | Master |
| 001 # MMDDYY# MMDDYY# |
‘Date setup’ (MM = 01 to 12; DD = 01 to 31; YY = 00 to 99) | ||
| 002 # HHMM# HHMM# |
‘Time setup’ (HH = 00 to 23; MM = 00 to 59) | ||
| Manual Passage |
399 # P# |
‘Activate / De-Activate Passage Mode’ (P = 0 or 1; 0 = disable Passage Mode; 1 = enable Passage Mode) | Master, Mgr |
| Global Lockout |
499 # L# |
‘Activate / De-Activate Lockout Mode’ (Master User doesn't affect by Lockout Mode) (L = 0 or 1; 0 = disable Lockout Mode; 1 = enable Lockout Mode) | Master |
| Diagnostic |
500 # 123456789*0# |
‘Manual diagnostic’ | Master, Mgr |
| 501 # | Identify if the lock is an E-Plex™ 5000, 5200, 5700, or 5800 | ||
| Communication Startup | 900 # | ‘Communications startup’ | Master, Mgr |