Visual Feedback Message Definitions for E-Plex 36xx/37xx/56xx/57xx Series Locks

Updated Feb 17, 2026

Visual Feedback Message Definitions for E-Plex 36xx/37xx/56xx/57xx Series Locks

Condition Parameters
  Green LED Red LED Duration Rate
Valid pushbutton pressed ON OFF 1/10 sec Once
Timeout expired OFF ON 1 sec Once
Valid access credential entered/presented ON OFF 1 sec Once
Access granted ON OFF 1/10 sec Once
Access granted (battery low condition) ON ON 1/10 sec 1 sec
Access denied OFF ON 1 sec 1 sec
Valid programming 
entry
ON OFF 1 sec Once
Invalid programming entry (including duplicate access credential) OFF ON 1 sec Once
Tamper shutdown beginning OFF ON 2 sec Once
Tamper shutdown state OFF ON 1 sec 10 sec
Tamper shutdown ending ON OFF 2 sec Once
*Communication starting ON OFF 1 sec Once
*Communication ending ON OFF 1 sec Once
*Communication aborted OFF ON 1 sec Once
*Communication in progress ON
(Alternate)
ON
(Alternate)
1/10 sec 1 sec
Deadbolt/Thumbturn
Privacy Activated
OFF On 1 sec Once
Deadbolt/Thumbturn
Privacy De-activated
ON OFF 1 sec Once
Hard reset sequence
in progress
On (Alternate)  On (Alternate)  1/2 sec. Continuously
Hard Reset sequence ended successfully ON OFF 2 sec. Once
Hard Reset sequence failed OFF ON 2 sec. Once

*When used with the E-Plex Maintenance Unit (M-Unit) handheld and software only