How to use the Configurable "Input Output" Table of USB Communication in Axessor Apexx Software?

Updated Feb 23, 2026

Answer

Resolution

Sort device I/Os 

Click the "I/O" heading. A blue arrow ascending/descending arrow indicates ascending or descending order.

Configure an I/O:

  1. Click the Edit button Pencil Icon (pencil) in the row of the desired I/O.
  2. Toggle the Normally Open / Normally Closed button to set the I/O state:
    • Normally Open button = I/O open when the lock is in normal (locked) state.
    • Normally Closed Button = I/O closed when the lock is in normal (locked) state.
  3. Enable the desired option by sliding the toggle to the right so it turns blue toggled icon.
  4. Click the Save button Save button to store changes.

Configurable Input Options:

  • Remote Disabling
  • Door Contact
  • Skip Time Delay

Configurable Output Options:

  • Lock Open
  • Time Delay Counting
  • Confirmation Window Count
  • Duress Code

Applies To

Axessor Apexx Software