Why should firmware be updated before setup?

Updating to the latest firmware provides several important benefits:

  • Ensures PIN syncing works correctly 
  • Enables additional dual-mode features (such as Manager + One) 
  • Includes the latest bug fixes 
  • Improves activation reliability on slow networks (firmware 2.0.2.5 and newer) 
  • Fixes lock sensor errors 

Best Practice: 
Update firmware before adding the lock system to the software whenever possible.

How are firmware updates performed?

  • If the system is NOT activated, firmware updates must be completed over USB. 
  • For Apexx systems, USB updates currently require a client connected to a licensed backend. 

If USB updating is not possible, firmware can generally be updated after activation.

Why is eBox commissioning important?

  • The eBox must be commissioned for the system to operate correctly.
  • A common issue is that installers add the lock but do not commission the eBox.

The customer must also receive and retain the admin/commission code used during setup in order to:

  • Configure networking 
  • Add devices 
  • Remove devices 
  • Shelve devices 

Without this code, activation may not be possible.

What network settings should be configured?

Recommended settings:

  • Enable = ON 
  • Mode = Local Server 
  • Verify the Local Endpoint server IP address is correct 

Does the server need to respond to ping requests?

No.

Some servers block pings. The system can still function properly as long as ports 5001 and 8883 are open through all:

  • Firewalls 
  • Routers 
  • Switches 
  • Gateways 

What does the blinking green light on the eBox mean?

A blinking green light indicates the eBox is successfully receiving an IP address from the router.

This is required for proper operation if:

  • Networking is enabled 
  • The eBox is commissioned 

Which firewall ports must be open?

Ports 5001 and 8883 must be allowed through all:

  • Firewalls 
  • Routers 
  • Switches 
  • Gateways 

How can connectivity be tested?

Connect a PC to the same Ethernet jack used by the eBox and test ports 5001 or 8883 using:

  • Telnet 
  • PuTTY 

When is a public IP address required?

A static public IP address and associated domain name are required if eBoxes or clients connect from outside the server’s local network.

Examples include:

  • Remote users 
  • Separate customer locations 
  • External VPN access 

How should configuration files be updated for public access?

Edit appsettings.json files:

Locations:

C:\Program Files (x86)\dormakaba\APEXX API

C:\Program Files (x86)\dormakaba\APEXX Broker

Make the following changes:

  • Replace "*" in the Kestrel URL with the server domain name 
  • Replace "localhost" with "127.0.0.1" in: 
    • ApiSettings 
    • BrokerHostSettings 

Edit ApexxClient.dll.config

Location:

C:\Program Files (x86)\dormakaba\APEXX Client\ApexxClient.dll.config

Change:

  • "localhost" to "127.0.0.1" in: 
    • APIURL 
    • MQTTEndpoint 

When are default configuration files acceptable?

Default configuration files are generally fine when:

  • All components are on the same network 
  • Different subnets can communicate 
  • Devices communicate through a VPN 

What should be checked with certificates?

Check:

  • Expiration dates 
  • SAN (Subject Alternative Name) entries 

The SAN list should include:

  • Local IP addresses 
  • Public IP address (if applicable) 
  • DNS name for the public IP 
  • 127.0.0.1 or localhost 

Note: The IP address or DNS used by the eBox or client must appear in the SAN list.

Where are Apexx Services (API & MQTT Broker) certificates located?

If using NT SERVICE accounts:

C:\Windows\ServiceProfiles\APEXX API\AppData\Roaming\Microsoft\SystemCertificates\My\Certificates

C:\Windows\ServiceProfiles\APEXX MQTT Broker\AppData\Roaming\Microsoft\SystemCertificates\My\Certificates

If using another user account:

C:\Users\username\AppData\Roaming\Microsoft\SystemCertificates\My\Certificates

Expired Certificates

Expired certificates are one of the most common causes of systems unexpectedly going offline.

To resolve:

  1. Delete expired certificates 
  2. Restart Apexx services 
  3. Re-register the software 

Important Note for Software Version 108.x and Newer

Do NOT delete:

  • Apexx Web API MQTT Client certificate 

This certificate may not regenerate automatically.

Only delete:

  • Apexx MQTT Broker certificate 
  • Apexx Web API Service certificate 

What if my lock system goes offline after about a year?

The eBox certificate may have expired.

For newer software:

Check:

  • Application Settings → Certificate Management 

For firmware 2.0.2.5 or older:

  • Deactivate and reactivate the eBox 
  • Use the claim code from the Lock Systems screen 

Newer firmware and software versions automatically renew certificates.

What are the most common login and startup problems?

“Login Not Found” Error

Possible causes:

  • Client cannot reach the server 
  • Services are not running 
  • User is not authorized 

If the client was connected to another server previously, the client certificate may be invalid.

To fix:

  1. Open certmgr.msc 
  2. Locate Apexx MQTT Client certificate 
  3. Delete the certificate 
  4. Restart the client software 

Services Will Not Start

Common causes include:

Invalid Kestrel URL

  • Do not use an IP address in the Kestrel URL 
  • Use a domain name instead 

Incorrect Endpoint Settings

If using a domain name:

  • Do NOT use "localhost" 
  • Use "127.0.0.1" instead 

SQL Permissions

If not using NT SERVICE accounts:

  • Service login users must have SQL sa permissions 

Configure this in:

  • SQL Server Management Studio (SSMS) 
  • Security → Logins 

Google Sign-In Problems

If Google authentication fails:

Delete: 
C:\Users\<username>\AppData\Roaming\Google.Apis.Auth

Then:

  1. Relaunch the client 
  2. Select “Sign in with Google” 
  3. Complete the browser login process 

The Google account must:

  • Be a valid software user 
  • Have Login Provider set to Google