What are the Lock Responses in Auditcon Models 252 & 552

Updated Feb 27, 2026

Lock Responses in Auditcon Models 252 & 552

Description

Auditcon locks provide visual and audible feedback during operations. The LEDs and beeps indicate power status, step acceptance, operation success or failure, and lockout periods.

Lock Responses

  • Power indication
    Two simultaneous green and red flashes Green and red flash and two beeps 2 horn sound indicate the lock is powered. 
    If no beeps sound, manually power the lock by turning the dial back and forth.
  • Keystroke feedback: After each key press, a green flash Green flash appears and a beep horn sound sounds if enabled. No response may indicate the lock is powered down or the key was pressed improperly.
  • Step acceptance: After each accepted operation step, simultaneous green and red flashes Green and red flash prompt for the next input.
  • Operation completion: After completing an operation, two simultaneous green and red flashes Green and red flash indicate success. Three red flashes 3 red flashes indicate failure; re-enter the operation.
  • Valid combination entry:
    • Dead Bolt: 1 slow green flash Green flash
    • Slide Bolt: continuous green flashes Green flash for ~5 seconds
  • Failed attempts: After 5 consecutive invalid entries, the lock disables for 3 minutes. 
    Slow red flashes Red flash display every 3–4 seconds and beeps horn sound sound if enabled. 
    Additional failed attempts reset the 3-minute disable.
  • Timed lockout: Series of three red flashes 3 red flashes with a pause, repeating while the lock is powered.
  • Battery Assist: When installed with a 9V Alkaline, LEDs flash continuously during Time Delay or Open Window periods and provide extra power for lengthy operations. 
    No battery-low indicator is provided.

Applies To

Auditcon Models 252 & 552