Description
Auditcon locks provide visual and audible feedback during operations. The LEDs and beeps indicate power status, step acceptance, operation success or failure, and lockout periods.
|
Lock Responses
-
Power indication
Two simultaneous green and red flashes and two beeps indicate the lock is powered. If no beeps sound, manually power the lock by turning the dial back and forth.
-
Keystroke feedback: After each key press, a green flash
appears and a beep sounds if enabled. No response may indicate the lock is powered down or the key was pressed improperly.
-
Step acceptance: After each accepted operation step, simultaneous green and red flashes
prompt for the next input.
-
Operation completion: After completing an operation, two simultaneous green and red flashes
indicate success. Three red flashes indicate failure; re-enter the operation.
-
Valid combination entry:
- Dead Bolt: 1 slow green flash
- Slide Bolt: continuous green flashes
for ~5 seconds
-
Failed attempts: After 5 consecutive invalid entries, the lock disables for 3 minutes.
Slow red flashes display every 3–4 seconds and beeps sound if enabled. Additional failed attempts reset the 3-minute disable.
-
Timed lockout: Series of three red flashes
with a pause, repeating while the lock is powered.
-
Battery Assist: When installed with a 9V Alkaline, LEDs flash continuously during Time Delay or Open Window periods and provide extra power for lengthy operations.
No battery-low indicator is provided.
|