How to Set Time Delay and Delayed Opening Window in Auditcon Models 252 & 552

Updated May 14, 2026

How to Set Time Delay and Delayed Opening Window in Auditcon Models 252 & 552

Description

This operation allows the Master User to define:

  • A Time Delay period (01–99 minutes)
  • A Delayed Opening Window (01–20 minutes)

The time delay begins immediately after a valid combination is entered. During the delay period, while powered, the lock displays two red flashes approximately every four seconds.

After the delay period expires, the user has 01–20 minutes (user-defined) to re-enter a valid combination. During this delayed opening window, the lock displays two green flashes with a beep every four seconds while powered.

If the lock powers down during the delayed opening window and is re-powered, it will behave the same as it did at the beginning of the delayed opening window.

If a valid combination is not entered within the delayed opening window, the lock will not open. Entering a valid combination after the window expires will start a new time delay period.

The default time delay setting is 0 minutes (the lock opens immediately after valid combination entry).

Note: Time delay settings can be changed at any time. Changes to delayed opening will not take effect until after the next opening.

Caution: When Time Delay is set, designated Users (Access or Subordinate) become Time Delay Override Users. Users with override capability cannot open the lock or be added to the lock once a Time Delay value has been defined.

  1. Press # then 5. The lock will display green and red flashes.
  2. Enter the Master User combination. The lock will display green and red flashes twice.
  3. Enter the desired Time Delay in minutes (01–99). The lock will display green and red flashes twice.

    Note: To disable Time Delay, enter 00.

  4. Re-enter the same Time Delay value for verification. The lock will display green and red flashes.
  5. Enter the desired Delayed Opening Window in minutes (01–20). This is the time allowed to enter a valid combination after the delay expires. The lock will display green and red flashes.
  6. Re-enter the Delayed Opening Window value for verification. The lock will display green and red flashes twice.

Applies To

Auditcon Models 252 & 552