Initial Lock Operation in Auditcon Models 252 & 552

Updated May 6, 2026

Question

How to do Initial Lock Operation in Auditcon Models 252 & 552

Answer

To test successful installation of the lock before you begin lock setup, perform the following operation.

WARNING: The container door should remain locked open until testing is complete.


To Unlock Using the Pre-Set PIN 

Your lock has been shipped so that any valid User ID for the lock model (except “00”) followed by the factory pre-set PIN of “502550” will open the lock.

  1. For a Dead Bolt, place the dial in the HOME position (i.e., the lip of the dial will cover the red “open lock” indicator.)
  2. Enter any valid two-digit User ID for the lock model (except “00”) followed by the pre-set PIN 502550 on the keypad. If the combination is entered successfully, the lock will respond as follows to indicate that the lock is ready to open:
    • Dead Bolt - 1 slow green flash
    • Slide Bolt - Continuous green flashes for approx. 5 seconds
    • For a Dead Bolt, dial right (clockwise) until the lock bolt is retracted and then open the container.
    • For a Slide Bolt, rotate the container handle while the green light is flashing ... to retract the bolt.

    Practice opening the lock several times with the pre-set PIN before you set a new combination.