Remove a lock from an operational mode in Auditcon Models 252 & 552

Updated Apr 25, 2026

Question

How to remove a lock from an operational mode in Auditcon Models 252 & 552?

Answer

To remove a lock from an operational mode, you can “shelve” the lock. This operation places the lock in Shelved Mode where most lock information is returned to the factory default settings. The only information retained from the operational mode is the audit information, the time delay setting, and holidays (if defined.) If a Time Delay setting, the time delay will then reset to the factory default of “0” after an unlock operation has been performed.

  1. Press # and then 2.
  2. Enter the Master User combination.
  3. Enter 08.
  4. Enter 08 again for verification.

Note: A green flash followed by three red flashes indicates that the lock does not have enough power to perform the shelving operation.


The lock will now open by entering any valid User ID for the lock model (except “00”) followed by 502550. You should test the opening of the lock with this combination.