Lock Operating Conventions in Auditcon Models 52 & T52

Updated May 5, 2026

Question

What are the Lock Operating Conventions in Auditcon Models 52 & T52?

Answer

Powering the Lock

  • The lock uses PowerStar™ Technology (internal generator).
  • Before each use, power the lock by briskly turning the dial back and forth.

Basic Functions

  • To clear an entry: press the * key.
  • After entering a valid combination:
    You must retract the bolt within 4–6 seconds, or the lock will relock automatically.

Bolt Type Behavior

Dead Bolt (Manual Locking)

  • Set the dial to the HOME position (covers the red open indicator).
  • To unlock: turn the dial clockwise (CW) to retract the bolt.
  • To lock: turn the dial counterclockwise (CCW) to extend the bolt.
  • Do not apply more than 5 lb of force to the bolt, or it may not open.

Slide Bolt (Auto Locking)

After a valid combination:

  • The bolt retracts automatically when opening.
  • The bolt extends automatically when locking.

Do not apply force to the bolt, or the lock will not open.