How to Set Time Delay and Delayed Opening Window on Auditcon Models 52 & T52?

Updated Feb 27, 2026

How to Set Time Delay and Delayed Opening Window on Auditcon Models 52 & T52?

Description

These instructions apply to Super Master operations on Auditcon Models 52 and T52. Time Delay restricts immediate access to the lock after a valid combination is entered. The Delayed Opening Window defines the time period during which the lock can be opened after the delay expires.

Resolution

Important Notes:

  • Changing the lock mode resets all combinations to the factory default (502550).
  • Any change to the delayed opening settings takes effect only after the next successful opening of the lock.
Step Action Lock Response
1 Press #, then press 5.

Green Flashes and Horn sounds

Green Flashes
Horn
2 Single Mode
Factory combination is 502550.
Enter the Manager User (User 1) combination. 

Green and Red Flashes 

Green Flashes
Red Flashes
3 Dual Custody Mode
Enter the first user combination. 
 

Green Flashes and Horn sounds

Green Flashes
Horn
4 Enter the second user combination

Green and Red Flashes 

Green Flashes
Red Flashes
5 Enter the Time Delay duration in minutes (01–99). To disable Time Delay, enter 00

Green Flashes and Horn sounds

Green Flashes
Horn
6 Re-enter the Time Delay value to confirm.  
If the value is not 00, continue to the next step.

Green Flashes and Horn sounds

Green Flashes
Horn
7 Enter the Delayed Opening Window duration in minutes (01–20)

Green Flashes and Horn sounds

Green Flashes
Horn
8 Re-enter the Delayed Opening Window value to confirm

Green and Red Flashes 

Green Flashes
Red Flashes

Applies To

Auditcon Models 52 and T52