The Alarm Interface should have resistors R1 to R5 populated, before setup, if the connections are to be used.

Setup – Alarm Interface to Lock

  1. Connect the Interface cable to the battery port of the lock
  2. Connect the bolt sensor cables to the Alarm Interface: 
      a. Normally closed cable to pin 1 
      b. Common cable to pin 2 
      c. Normally open cable to pin 3
  3. Connect door sensor leads to pins 6 & 7.

Setup – Alarm Interface to Alarm System

  1. The bolt arm/ disarm connections are made to pins 9, 10 & 11. Pins 9 & 10 are normally closed (NC). Pins 10 & 11 are normally open (NO). When using only 2 wires short either R1 or R2 (NC connection) to “C” using a resistor.
  2. The tamper pins 12 & 13 are connected through the normally closed (NC) switch.
  3. The door arm/ disarm connections are made to pins 14 & 15.
  4. The Remote disabled connections are made to pins 16 & 17 with 12 V, 5 mA.
  5. The Silent Duress signal from the lock connected through pins 18 & 19 triggers the relay switch for 1 second.

Setup – Test

Test the system’s functioning before activating the alarm system:

Bolt sensor

  1. Connect the lock to the Alarm Interface.
  2. Close lock – pins 1 & 2/ 9 & 10 are closed.
  3. Operate lock; Enter opening code.
  4. Pin 2 & 3/ 10 & 11 are closed

Remote disable

  1. Activate the Remote Disable (12 V DC, 5 mA) to pins 16 & 17.
  2. Operate lock; Enter opening code. Lock signals beeps 6 times. Lock does not open as long as the Remote Disable is activated.

Silent duress 

  1. Operate lock; Enter Silent Duress code – Last digit ± 1. Relay switch opens 1 second.
  2. Pins 18 & 19 open 1 second.

Circuit diagram

alarm interface diagram

Lock and Door Setup