Super Master Reset in ComboGard Pro 39E Electronic Combination Lock

Updated Apr 29, 2026

SMR will reset the lock back to factory state, but the SM code remains unchanged. The default code of 5-5-5-5-5-5- 5-5 must be changed before the Manager default code is changed or the Super Master Reset function will be permanently lost.

Process is as follows:

  1. Action - Press and hold [0] key for 3 seconds
  2. Result – Lock beeps twice and the LED remains ON throughout the entire process
  3. Action – Enter default code of 5-5-5-5-5-5-5-5. Press and hold last digit until the unit gives a double beep.
  4. Result – Command Menu access is granted.

SMR has only 2 Command options available:

Change Code

  • If press [0] = Change Code, (1 time use)
  • Enter current default Super Master code of 5-5-5-5-5-5-5-5
  • Enter new Super Master code (ex. 8-8-8-8-8-8-8-8) then double beep.
  • Enter new Super Master code again to confirm (ex. 8-8-8-8-8-8-8-8) then double beep the SMR code is set.

NOTE:  Once the default code is changed to a new code the code can never be changed. A reset box must be used to reset.


Reset Code

  • If press [8] = Reset the Lock
  • Lock will signal a long beep to indicate it was reset
  • If any other key is pressed then the lock beeps 3 times and the operation is ended.