Initiate Silent Alarm in ComboGard Pro 39E Electronic Combination Lock

Updated Feb 20, 2026

Initiate Silent Alarm in ComboGard Pro 39E Electronic Combination Lock

(Alarm Box Required - P/N 2789-NC)

  • Using a Motor Blocking Lock (code level v1.07 or higher): 
    add or subtract (+/-) 1 to the last digit of the combination(s).
    Example: Combination: 1-2-3-4-5-6 Duress Combination: 1-2-3-4-5-5 or 1-2-3-4-5-7
  • Using a Solenoid Lock: 
    add (+) or (-) 1 to the last digit of the combination(s).

    The Lock will open without any indication that the alarm signal has been sent.