972 9 Series Illuminated Pushbutton Installation Instructions

Updated Mar 26, 2026

972 9 Series Illuminated Pushbutton Installation Instructions

Instructions

  1. A 2-1/4” (57mm) deep back box is required. Match your message color with lens cap color and snap into the housing. Slide connectors onto the terminals as shown.
  2. To change the LED voltage, slightly turn the white lamp holder in a counterclockwise direction to release from the black housing and pull it out. Change LED cluster as desired and re-turn the lamp holder back into place.
  3. Connect appropriate 12 or 24 VDC supply voltage to the LED terminals on each side of the switch.  Remember that the LED (+) positive and (-) negative terminal is determined by the lamp position in the base. If bulb does not light, reverse position of leads.
  4. To change the message tag, remove the lamp holder as described above and then pinch the white tabs to release the lens cap. Be careful not to lose the spring. Insert your thumbnail between the corner of the lens cap and white extension and then slide it along the edge to separate the cap. Tap the cap to remove the message tag.

NOTE: Overheated / melted components caused by incorrect input voltage not be covered under warranty.

Exploded and rear view diagrams of the RCI 972 illuminated pushbutton showing lamp holder, LED cluster, lens cap, message tag, button housing, and labeled COM, NO, NC, and lamp terminals.
Bulb Voltage Current Draw Switch rating
LED 12VDC 20mA Cycle Rating: 10,000
LED 24VDC 10mA Contacts Rated 16 amp @ 125VAC