910TC Touchless Switch Installation Instructions

Updated May 4, 2026

Front view of RCI 910TC touchless switch showing capacitive and infrared sensing ranges.
Figure 1

The RCI 910TC is a dual-technology (capacitance and infrared) touchless switch with a mechanical override that serves as a backup in the event of power or electronic failure. This touchless switch will fit with door frame mounting installation and is ideal for areas where hands-free access is desirable for sanitary or other logistical reasons.

Functions

• The user waves his/her hand in front of the switch to trigger the device. The backlight of the device will turn from blue to green. At the same time, the relay will activate and the buzzer will beep.

• Relay activation time can be adjusted via the DIP switches to 1-7s (device must be repowered after setting DIP switches).

• Buzzer is controlled by DIP switch or trigger, subject to the last setting. Trigger the door button three times continuous, after the fourth time, stay in the range of induction until there was a long beep.

• Supports mechanical override (press the front panel to trigger the device).

• Support remote module (Optional).

Operating 
Voltage

Operating
Current

Operating
Temperature

Relays

Trigger Distance

Operating Humidity

+10V ~ +24VDC

100mA max
(@12VDC)

-10oC ~ 70oC

Dry contact output
(Maximum load 1A@30VDC)

3 ~ 5cm (Capacitance), 5
~ 10cm (Infrared), 5 ~ 7cm
(Capacitance & Infrared)
There may be slight
differences in actual use due
to environmental effects

10 ~ 90%RH, no
condensation

Wiring Method: (see Figure 2)

No.

Color

Label

Description

Wiring diagram for the RCI 910TC
Figure 2

1

Blue

MO

Manual door opening input, low level

2

Red

VDC

Power input (+10V~+24VDC)

3

Brown

GND

Grounding (0 VDC)

4

Black

RTE_NO

Touchless switch signal output (dry contact)

5

Orange

RTE_COM

6

Purple

RTE_NE

DIP Switch Definition: (See Figure 2)

The DIP switches control sensing modes, timing, buzzer behavior, and anti-interference settings.

Note: Power Off When Adjusting DIP Switches

1

ON

DIP 1, 2, 3
combination, can
adjust the relay
working mode and
action time

Switching Mode

Enable: DIP 1-3 are OFF at
the same time.
Disable: the state of at least
one is ON in DIP 1-3

Trigger once, the relay output maintains open,
GLED lights.
Trigger again, the relay output close, GLED go
out, BLED lights.

OFF

2

ON

Timing Mode
(1-7s)

D-SW1

ON

OFF

ON

OFF

ON

OFF

ON

OFF

D-SW2

OFF

ON

ON

OFF

OFF

ON

ON

3

ON

D-SW3

OFF

OFF

OFF

ON

ON

ON

ON

OFF

Time(s)

1

2

3

4

5

6

7

4

ON

Infrared

Turn on Infrared Sensing

OFF

5

ON

Buzzer

Turn on trigger beep sound

OFF

6

ON

Anti-interference

When there are more sources of interference in the field environment, you can open the anti-interference mode (this parameter is only for capacitive induction)

OFF

7

ON

Turn off
capacitance

Turn off capacitance sensing

OFF

Turn on
capacitance

Turn on capacitance sensing (*Default)

8 N/A N/A N/A

Installation Instructions

1) Remote Control Module Installation (Optional): 

When extra remote control is available, the remote-control module shall be inserted into the holes. Insert the 6 pins of the module (Figure 3) into the correct holes of board (Figure 4 & 5).

Remote control module for the RCI 910TC shown from multiple angles, including connector pins and module housing.
Remote Control Module
Figure 3
Rear view of the RCI 910TC switch with the optional remote control module not installed.
Switch with Remote Control
Module Uninstalled
Figure 4
Rear view of the RCI 910TC switch with the optional remote control module installed on the circuit board.
Switch with 
Remote Control
Module Installed
Figure 5

2) Touchless Switch Installation:

  1. Hold the left and right sides of the device and pull outward with your fingers along the top, as shown in (1) in Figure 6, then pull down the front cover.
  2. Refer to the dimension size diagram of the exit button as shown in Figure 8.
  3. Connect the wires according to the Wiring Method chart. 
  4. Install the module body to your surface using the supplied screws as shown in (2) in Figure 7.
  5. Secure the M-type buckles of the cover into the slot at the bottom of the module, as shown in (3) in Figure 7, then push the upper part of the cover up as shown in (4) in Figure 7.
Illustration showing removal of the front cover of the RCI 910TC touchless switch during installation.
Figure 6
Installation diagram showing mounting screws and attachment of the RCI 910TC switch body to the wall or surface.
Figure 7
Dimension diagram of the RCI 910TC touchless switch showing front, side, and rear views with metric measurements.
Figure 8

Cautions

1) When DIP switches 4 and 7 are ON, the device will not be triggered. When DIP switches 4 and 7 are OFF, the device requires detection by both the IR and capacitor sensors for it to be triggered.

2) When the devices environment changes (such as moving it or removing the panel), it will take about 5 seconds to adapt to the environment. Please trigger the device after it finishes the adaptive adjustment.

3) When waving, please pause your hand in front of the panel. Waving too fast may not be able to trigger the device.

FCC Regulatory Statements

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and

(2) This device must accept any interference received, including interference that may cause undesired operation.

NOTE: ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.