970 Illuminated Exit Button Installation Instructions

Updated Mar 26, 2026

Instructions

  1. Slide the colored leads onto the switch terminals according to the diagram below.
  2. Check all connections to ensure that they are properly attached to the terminals. Fail secure and fail safe have different connections.
  3. Connect leads to electric lock and check for proper operation, then fasten the plate to a utility box (supplied by others). 

“N” narrow version (1-5/8” x 4-3/4”) is compatible with 1-3/4” (or larger) narrow-frame profiles. Blue cap is standard.

Switch Terminals

2 SPST 1 N/O 1 N/C

Rear view of RCI 970 illuminated exit button showing 2 SPST terminals with normally open and normally closed contact positions.

Rear View

#1 and #2 Normally closed for fail safe systems
#3 and #4 Normally open for fail secure systems
A and B Pins that power the lamp of push button
+ - Match voltage marked on back of faceplate & packaging

DMO & DMA
4 SPST 2 N/O 2 NC
 

Rear view of RCI 970 DMO and DMA illuminated exit button showing 4 SPST terminals with two normally open and two normally closed contacts.


Rear View

Profile Detail

Installation overview of the RCI 970 illuminated exit button showing wiring instructions, switch terminal configurations, and front and side profile dimension diagrams