Mechanical Binding at the Strike or Rods
Excessive mechanical resistance may prevent latch retraction.
Check for the following:
- Latches rubbing against the strike
- Vertical rods not centered
- Vertical rods misaligned or skewed
- Top rod out of adjustment
If any binding is present, correct the mechanical alignment and re-test.
-
Yoke Assembly Pin Condition
A misaligned or damaged yoke pin can prevent proper solenoid movement.
Inspect the yoke assembly pin for:
- Misalignment
- Rubbing
- Burrs or surface damage
If damage or interface is found, correct or replace the affected components. See Image in Additional Information Section Below.
-
Electrical Resistance in Wiring
Excessive resistance can prevent the solenoid from developing sufficient force.
Test Procedure:
- Turn off power to the ELR150 power supply
- At the terminal block 2, measure resistance across:
- Pin 1
- Pin 2 (white wires)
Expected Measurement:
- Resistance must be between 4.5 and 6.0 ohms
If resistance is outside this range, inspect wiring and connections for faults.