Which power supplies should be used with the different electrical options on the BEST exit devices?

Answer

ALW/WALW – Alarm – PS161-6 can run up to 8 devices.  Any 24VDC filtered and regulated power supply with .25 amps per device can be used.

DE – Delayed Egress – PS161-6.  Each power supply can run up to 4 devices.  No other power supply can be used due to the UL listing.

E – Electric lock/unlock of the trim – RPSML2 or RPSMLR2BB can run up to 2 devices.  The PS161-6 can run up to 8 devices.  Any 24VDC filtered and regulated power supply with .3 amps per device can be used.

ELR – Electric Latch Retraction – ELR151, ELR152, ELR153, or ELR154 depending on the number of devices.  No other power supply can be used.

MLR – Motorized Latch Retraction – RPSMLR2 or RPSMLR2BB.  The BB is for battery backup.  Each power supply can run 2 devices.  Any 24VDC filtered and regulated power supply with 1.5 amps per device can be used.

Additional information

Here are the links to the instructions.

ELR150

https://dhwsupport.dormakaba.com/hc/article_attachments/4415914437787

https://dhwsupport.dormakaba.com/hc/article_attachments/4415898074139

https://dhwsupport.dormakaba.com/hc/article_attachments/4415968273563

RPSMLR2

https://dhwsupport.dormakaba.com/hc/article_attachments/25772775110043

PS161-6

https://dhwsupport.dormakaba.com/hc/article_attachments/11123728882459

Applies To