Electric Latch Retraction, ELR, Wiring Instructions and Specifications

Updated May 8, 2026

Electric Latch Retraction

Electric Latch Retraction

Instructions

Document ID

Description

T93581  ELR Wiring Detail and Door Preparation Information
T93581_SP Detalles del cableado de retracción del pestillo eléctrico (Spanish)
T93581_FR Détails du câblage de rétraction du pêne électrique (French)
T93580 

ELR Retrofit Kit Installation Instructions

  • ELRK-3, ELRK-4, ELRKF-3, ELRKF-4
  • NELRK-3, NELRK-4, NELRKF-3, NELRKF-4
T93580_SP Kit de conversión ELR (STD y BF) - ELRK y ELRKF para dispositivos de montante ancho Instrucciones de instalación de NELRK y NELRK para dispositivos de montante estrecho
T93580_FR Trousse de conversion ELR (STD et BF) – ELRK et ELRKF pour dispositifs à montants larges Instructions d’installation NELRK et NELRKF pour dispositifs à montants étroits
T93665  CM150-08 Control Module Wiring Instructions for CM150-05 to ELR
T93665_SP Instrucciones de instalación del módulo de control CM-150-08 (Spanish)
T93665_FR Instructions d’installation du module de contrôle CM-150-08 (French)
T93666 

Power Supply Installation Instructions

  • ELR150, ELR151, ELR152, ELR153
T93666_SP

 Instrucciones de instalación de la fuente de alimentación ELR-150 (Spanish)

  • ELR150, ELR151, ELR152, ELR153
T93666_FR

Instructions d’installation de l’alimentation ELR-150 (French)

  • ELR150, ELR151, ELR152, ELR153
T93669  BT150-07 Battery Backup ELR Power Supply Wiring Instruction
T93669_SP Fuente de alimentación ELR con batería auxiliar BT-150-07 Instrucciones de cableado (Spanish)
Wiring Instructions(Spanish)
T93669_FR Alimentation ELR de la batterie de secours BT-150-07 instructions de câblage (French)

Specifications

ELR Specifications

  • Provides remote electric latch retraction for exit devices
  • Uses continuous-duty solenoids for momentary unlatching or continuous dogging
  • Interfaces with door operators, card readers, switches, and fire alarm systems

Number of Devices

Door Width

3

2′-7″ to 3′-0″

4

3′-1″ to 4′-0″


The Power Supply model number is determined based on the number of devices requiring electrical power.


ELR Conversion Kit


A standard device can be retrofit to the Electric Latch Retraction option by ordering the kits listed below. A ELR Conversion Kit REQUIRES a ELR150 Series Power Supply. To Order:
 

Stile Type / Width

Compatible Devices

Wide Stile – 3′-0″

ELRK-3, ELRKF-3

Wide Stile – 4′-0″

ELRK-4, ELRK-4

Narrow Stile – 3′-0″

NELRK-3, NELRKF-3

Narrow Stile – 4′-0″

NELRK-4, NELRKF-4

ELR Conversion Kit


Note: Power may be supplied through a 4-wire continuous circuit hinge (furnished by others).

Solenoid Specifications

Operating Mode Electrical Rating
Current Pulse (maximum 2 seconds) 4.75 amps
Continuous Duty 3.6 VDC at 0.8 amps

ELR150 Series Power Supply

  • Supplies required power for all ELR devices
  • Supports up to four plug-in control modules
  • Controls one ELR device per control module
  • Provides an adjustable latch retraction delay from 0 to 4 minutes

Power Supply Specifications

  • Meets UL Class II output requirements
  • Complies with UL 294 access control standards
  • Protects circuitry using integrated circuit breakers
  • Accepts 115 or 230 VAC user-selectable input
  • Operates at 115 VAC, 1 amp input
  • Supports optional battery backup and power tap
  • Displays power status using an LED indicator
  • Secures components inside a keyed, lockable enclosure
  • Measures 16″ W × 14″ H × 6″ D
  • Weighs approximately 15 pounds