This article provides complete resources for Exit Alarms, including ALK, ALM, and WALM models. It covers installation instructions and technical specifications.

ALK, ALW, WALW Exit Alarms 

Exit Alarms

Instructions

Document ID Description
T93642 Exit Alarm Series Instruction (ALK or ALW)
T93642_SP Alarme de sortie séries ALK, NALK, ALW et NALW instructions d’installation (Spanish)
T93642_FR Mode d'emploi de la série d'alarmes de sortie (ALK ou ALW) (French)
T93670 Weatherized Exit Alarm (WALW) Instruction 
T93670_SP Serie WALW: instrucciones de instalación de la alarma de salida resistente a la intemperie. (Spanish) 
T96670_FR Série WALW : instructions d’installation de l’alarme de sortie à l’épreuve des intempéries (French)

Specifications

Exit Alarm Specifications 

Exit Alarm Specifications

The Exit Alarm audibly monitors exit device use.

  • Supports all Apex Series devices
  • Sounds an alarm when the touchbar depresses
  • Delivers an 80 dB alarm at 10 feet
  • Displays system status using an LED indicator
  • Flashes green for 20 seconds during arming
  • Flashes red every 20 seconds when armed

ALK

  • Operates on battery power
  • Includes one 9-volt battery
  • Provides an audible low-battery alert
  • Supports remote arm/disarm or alternate input activation

ALW

  • Uses remote power at 12–24 VDC, 0.25 amp
  • Requires a two-wire power transfer (not included)
  • Supports external arm/disarm control
  • Supports external alarm activation

Weatherized Exit Alarm

  • Supports all Apex Series devices
  • Matches standard Exit Alarm operation
  • Adds a weatherized design for exposed environments

WALW – Remote Powered

  • Uses remote power at 12–24 VDC, 0.25 amp
  • Requires a two-wire power transfer (not included)
  • Resists moisture and outdoor exposure
  • Meets MIL-STD-810F Method 506.4 driving rain requirements
  • Meets MIL-STD-810F Method 509.4 salt fog requirements
  • Requires adding the WALW suffix to the device number when ordering

Cylinder

The Exit Alarm uses a standard 1-1/4-inch mortise cylinder as a key switch.

  • Arms the alarm and starts a 20-second exit delay
  • Silences and resets the alarm after unauthorized egress
  • Disarms the alarm for continuous unmonitored egress
  • Engages mechanical dogging on non-fire-rated devices

Wiring Harness – WH495

The wiring harness supports one or both options below.

  • Arms the alarm using alternate inputs
  • Requires a two-wire power transfer hinge for non-DS880 or NDS986 switches
  • Arms or disarms the alarm from a remote location
  • Requires a cylinder or dummy cylinder (not included)

Exit Alarm Kit

  • Fits Apex devices for 3-0 to 4-0 wide doors
  • Includes a touchbar warning decal
  • Supports retrofit installation on existing devices
  • Uses different channel filler lengths for narrow and wide stile devices

Stile Type / Width

Compatible Devices

Wide Stile – 2′-6″ & 3′-0″

ALK-3, ALW-3

Wide Stile – 4′-0″

ALK-4, ALW-4

Narrow Stile – 3′-0″

NALK-3, NALW-3

Narrow Stile – 4′-0″

NALK-4, NALW-4

Alarm Kits

All Finishes

  • 605: Bright Brass
  • 606: Satin Brass
  • 612: Satin Bronze
  • 613: Oil-Rubbed Bronze
  • 625: Bright Chrome
  • 628: Satin Aluminum
  • 630: Satin Stainless Steel