Description
When a user no longer requires access, delete their User Access Code. This frees the code number for assignment to a new user.
|
Resolution
Required User Level: Master, Manager
- Put the lock into Pushbutton Programming Mode.
- Enter the command to add or modify a User Access Code: 100#
- Enter the User ID location (three-digit number) followed by #: e.g., 023#
- Enter the User Access Code (4–8 digits depending on procedure settings) followed by #: e.g., 1024#
-
Re-enter the same code for confirmation: 1024#
Example of complete entry: 100#023#1024#1024#
- Press # to indicate the end of programming.
- The User Access Code is now active and grants all access privileges assigned to that user.
|
Additional Notes
- De-activating an old code does not allow you to add a user with the same number. De-activation should only be used temporarily, e.g., when the user is on vacation.
- User ID locations are three-digit numbers assigned by the Master or Manager. Maintain an accurate list of ID locations and their assigned users for proper lock programming.
|
Applies To
E-Plex 2000 Series Locks PowerPlex 2000 Series Locks
|