How to deactivate a Service User Access Code in E-Plex 2000 and PowerPlex 2000 series locks?

Updated Feb 17, 2026

How to deactivate a Service User Access Code in E-Plex 2000 and PowerPlex 2000 series locks?

Description

Deactivate a Service User Access Code temporarily during events such as a Service User’s absence, or if you created an Access Code but have not yet assigned it to a Service User. Time periods for Service Users continue to decrement if the code is deactivated, not deleted.

Resolution

Required User Level: Master, Manager

  1. Put the lock into Pushbutton Programming Mode.
  2. Enter the command to deactivate a Service User Access Code: 
    402#
  3. Specify the Service User ID location: 
    402#NNN#, where NNN is the specific Service User ID location (e.g., 025).
  4. Example of a complete entry: 
    402#025#
  5. Press # to indicate the end of programming.
  6. The Service User Access Code is now deactivated.

Applies To

E-Plex 2000 Series Locks
PowerPlex 2000 Series Locks