Users - General Information E-Plex 2000 and PowerPlex 2000

Updated Feb 3, 2026

Users – General Information

This article provides general information about user roles, access codes, keypad behavior, and timing rules for E-Plex and PowerPlex electronic locks.


User Roles and Access Codes

  • Master and Manager users can perform two functions:
    • Open the door by entering the access code without using the # key.
    • Enter Pushbutton Programming Mode by entering the # key before and after their access code.
  • Each user (Manager User, Service User, or Access User) occupies one of the 100 available user locations in the user table.
  • By default, user location 000 is assigned to the Master User.

Keypad Timing Rules

  • Users must enter the complete key sequence within 15 seconds.
  • Users have a maximum of 5 seconds between each keypress.
  • If a user exceeds either time limit, the lock:
    • Aborts the current programming sequence
    • Automatically exits programming mode
    • Displays a Keypad Timeout feedback message

Correcting Input Errors

If an invalid entry occurs during a command sequence, press the * key to clear all input entered since the beginning of the current command.

This action resets the programming sequence and restarts the 15-second time limit, allowing the user to re-enter the complete access code.