SAM RF™ Frequently Asked Questions

Updated Feb 26, 2026

SAM RF™ Frequently Asked Questions

This section provides answers to common questions about the SAM RF™ system.

How can I create a vendor key that lasts longer than a Limited Use key?
If your site uses Zone keys, create a Zone key with a defined shift time and expiration date. Note that a Zone key grants access to all units within the assigned zone.
What type of batteries does the utility device use?
The utility device uses rechargeable NiCad batteries. Do not install alkaline batteries. Alkaline batteries may explode when placed in the charger.
Why do all keys work except the Limited Use key?
The lock’s date and time are incorrect. Use the utility device to reset the lock’s date and time.
What does it mean when the lock shows no lights when a key is used?
The lock batteries are dead. Use the EPS or the utility device in battery backup mode to open the lock, then replace the batteries (see Section 6.7, “Opening a Lock with a Dead Battery”).
How can I determine why a key is not working?
Read the key to confirm it is valid and not expired. If the key appears correct, use a Diagnostics key to identify the issue (see Sections 5.15 and 8.16).
How long do lock batteries last?
Lock batteries typically last up to two years, depending on usage.
Do I need to update the lock for daylight saving time?
No. The lock automatically adjusts for daylight saving time. For best accuracy, update the lock’s date and time once per year using the utility device (see Section 6.5).
How long do the utility device batteries last?
With a full charge, the batteries last approximately three to five hours while in use.
Can I create keys if the utility device is not in the encoder base?
Yes. The encoder base charges the utility device but is not required to create keys.
Why does a Resident key not work in some common area locks?
Read the key to verify that the common access locks were assigned. If they were, recreate the key as a duplicate Resident key.
What should I do if a staff member loses a key?
Create an Inhibit Master or Inhibit Zone key, depending on the key type. Use the Inhibit key on every lock that the lost key accessed.
Can the SAM RF system be networked?
Yes. Install the SAM RF software on multiple computers and follow the instructions in Section 2.3.
Can SAM RF integrate with property management systems?
Yes. Integration requires custom interface software developed by Kaba and the property management provider. Additional fees apply.
Can I change the password timeout?
No. The system automatically logs out after five minutes of inactivity.
How often should I back up my database?
Follow the steps in Section 4.14. Back up the database daily.
How do I order parts?
Contact Customer Service at 800-849-8324.
How do I request service or technical support?
Contact Customer Service at 800-849-8324.