Follow these steps to retrieve a Cencon change key left locked after any process:
- Power Up the Lock: Turn the dial to the left.
- Check Display: If the lock shows "tEC", it detects the change key inside.
- Enter Code: If prompted, enter the code and present the key. The lock may display a lightning bolt.
- Wait for LCD: Allow the LCD to turn off.
- Power On the Lock: Turn the dial to the right.
- Observe Display: The lock will display "G2 → EC".
- Enter Code: Enter the code from your dispatcher or bank mode combination.
- Touch Key to Reader: When "IPI" appears, touch your key to the reader.
- Lock Displays "OPr": The lock will now display "OPr".
- Open Lock and Retrieve Key: Turn the dial to the right, open the lock, and retrieve the change key.
- Close Container: Close the container, retrieve the close code, and return it to the dispatcher if the open code was provided by them.
|