Follow the steps below if the lock display is stuck showing DL, which indicates that the lock believes the bolt is still extended.

The pin set contains a magnetic sensor that detects a magnet passing from right to left. This signal tells the lock that the bolt has been extended. If the magnet or sensor does not function correctly, the lock may remain stuck on DL.

Step 1: Verify the Magnet on the Dial Gear

Ensure that the magnet on the dial gear is properly positioned and aligned. A misaligned or damaged magnet can prevent the lock from detecting bolt movement correctly.

Close-up image of a lock display showing “DL,” indicating the lock believes the bolt is extended due to a sensor signal.
 

Step 2: Inspect the Magnet on the Dial Gear

Check that the magnet is securely attached to the dial gear and has not shifted or loosened. Reposition or replace the magnet if necessary.

Close-up image showing the magnet mounted on the dial gear, which is used by the lock’s sensor to detect bolt movement.
 

Step 3: Remove and Inspect the Ribbon Cable / Pin Set

  1. Remove the Torx screw securing the pin set.

  2. Gently pry the PCB away from the lock case.

  3. Try straightening the pin carefully.

    • If the pin snaps or is damaged, replace the lock case or pin set.

If the ribbon cable or pin set is damaged, the lock may incorrectly report the bolt status.

Step-by-step images showing removal of the Torx screw, gentle prying of the PCB from the lock case, and inspection of the ribbon cable and pin set for damage.

Applies To