Instruction to Read Command #70 on a Cencon Lock

Updated Feb 23, 2026

Instruction to Read Command #70 on a Cencon Lock

Command #70: Display Active Modes and Activator Identification

Without the need for a user key or an audit key, you can determine the following information on the lock:

  • Active Modes:
    Identify which modes are currently active on the lock: FL (First Line Maintenance), ro (Route), or bA (Bank mode).
  • Access Type:
    Determine if the mode is in Single (1) or Dual (2) access.

If the activating company used a USB Key Box with version 4.0 or higher software, additional security features are enabled on the lock. For example, Command #70 will display the following details instead of showing zeros, which is the case if the lock was activated with a version below 4.0 or using a PCI card system:

  • Company Code (Cn-):
    A unique 4-digit code assigned by Dormakaba to the company that activated the mode. This helps vendors identify the company responsible for service needs at the ATM.
  • USB Key Box ID (bn-):
    A 4-digit number assigned to the customer's USB Key Box that created the activation key. This assists in tracking and deterring potential security violations.

Example Output:

01- 1FL Cn 00 00 bn 00 00
02- 1ro Cn 00 00 bn 00 00
03- 2bA Cn 00 00 bn 00 00

Where:

  • "FL" indicates First Line Maintenance mode.
  • "ro" indicates Route mode.
  • "bA" indicates Bank mode.
  • "1" prefix indicates Single access mode.
  • "2" prefix indicates Dual access mode.
  • "Cn" precedes the company code.
  • "bn" precedes the USB Key Box device ID.