To retrieve an audit from a Cencon lock, first initialize a Supervisor Audit (SA) Key. Follow these steps:
1. Initialize the SA Key
- Insert the SA Key into the PC key reader running Cencon software.
- Open Cencon Software and go to the Main Menu.
- Click "Initialize Audit Download Key".
- If the key is for a Bank Mode lock:
- Check the box for Bank Mode.
- Select the Bank Branch Name associated with the lock.
- Click "Initialize Key" to complete the process.
- The SA key must be initialized before retrieving an audit.
- If not initialized properly, it may cause unpredictable results in the audit.
2. Retrieve Audit from the Lock
- Power the Lock: Turn the dial counterclockwise (CCW) until the lock displays "G 2 → EC".
- Initiate Audit Download:
- Press #0 on the lock keypad.
- For Gen2 locks, the lock shows "-dL" (dial left).
- Turn the dial CCW to power the lock until "ISA" appears.
- Insert the SA Key:
- When "ISA" appears, insert the initialized SA Key into the lock's reader.
- The lock displays "Aud" (Audit in Progress) with a flashing bar over "u".
- Complete the Download: Keep the SA Key in place until "EOP" (End of Operation) appears.
- Remove SA Key & Return for Reporting:
- Remove the SA Key from the lock.
- Return the key to the dispatch center to extract audit data using Cencon software.
3. Review the Audit in Cencon
- Insert the SA Key containing the audit into the key reader.
- Open Cencon Software and select "Key Report".
- View or print the audit data for analysis.
|