Procedure
- Retrieve the audit count from the lock by powering it up.
- Turn the dial to the left and press ##, then apply the key. The display shows a value such as SC-00 07, which indicates an audit count of 7.
- Retrieve the close code by pressing #4, then apply the key. The display shows a value such as C89.
-
Contact the Control Centre and request the audit count stored in the computer system.
Note: The audit count on the computer must match the audit count on the lock.
- If the computer audit count is lower than the lock audit count (for example, 6 instead of 7), the Control Centre must apply a closing code to synchronize the system.
- The Control Centre may request the engineer’s key number to reassign the opening code to that key. After issuing a new opening code, complete the following steps:
- Power up the lock and enter the issued code.
- Do not apply the key.
- Wait approximately 4.5 minutes.
- Attempt to open the lock using the normal procedure (code, then fob). The lock displays "LCO". This is expected.
-
Repeat the sub-steps above. On the third attempt, the lock displays "OPR".
Note: Depending on previous failed attempts, additional repetitions may be required.
- The lock is now removed from Lockout (LCO) mode.
|