Required Items
- R Key
-
 F Key
- Change Key
- SA Key
- Service Call Combination
- Activation Combination
Activation Procedure
- Power up the lock by turning the dial CCW until "EC" is displayed.
- Enter the FLM Service Call Combination. "IPI" is displayed.
- Insert and hold the F or R Key in the key reader until "OPr" is displayed.
- Turn the dial CW to open the lock.
- Open the door.
- Insert the Change Key into the Change Key Socket.
- Do not close the door. Turn the dial CCW until "EC" is displayed.
- Enter the Factory Combination 50-25-50. "ISA" is displayed.
- Insert and hold the SA Key in the key reader until "POC" is displayed.
- Pull out the Change Key. "OPr" is displayed.
- Turn the dial CW to open the lock.
- Do not close the door. Turn the dial CCW until "IPI" is displayed.
- Insert and hold the F Key in the key reader until "Close Seal" is displayed.
- Record Route Service Call Close Seal.
- Turn Dial CCW until "EC" is displayed.
- Enter FLM Activation Combination. "IPI" is displayed.
- Insert and hold F Key in Key Reader until "OPr" is displayed.
- Turn Dial CW to Open Lock.
- Close Door.
- Turn Dial CCW to close Lock until "IPI" is displayed.
- Insert and hold F Key in Key Reader until "Close Seal" is displayed.
- Record FLM Activation Close Seal.
- Report Close Seals to Dispatcher(s).
|