Required Items
- R Key
-
 F Key
- Change Key
- SA Key
- Service Call Combination
- Activation Combination
Activation Procedure
- Power up the lock by turning the dial CCW until "EC" is displayed.
- Enter the FLM Service Call Combination. "IPI" is displayed.
- Insert and hold the F or R Key in the key reader until "OPr" is displayed.
- Turn the dial CW to open the lock.
- Open the door.
- Insert the Change Key into the Change Key Socket.
- Do not close the door. Turn the dial CCW until "EC" is displayed.
- Enter the Factory Combination 50-25-50. "ISA" is displayed.
- Insert and hold the SA Key in the key reader until "POC" is displayed.
- Pull out the Change Key. "OPr" is displayed.
- Turn the dial CW to open the lock.
- Do not close the door. Turn the dial CCW until "IPI" is displayed.
- Insert and hold the F Key in the key reader until "Close Seal" is displayed.
- Record the FLM Service Call Close Seal.
- Turn the dial CCW until "EC" is displayed.
- Enter the Route Activation Combination. "IPI" is displayed.
- Insert and hold the R Key in the key reader until "OPr" is displayed.
- Turn the dial CW to open the lock.
- Close the door.
- Turn the dial CCW until "IPI" is displayed.
- Insert and hold the R Key in the key reader until "Close Seal" is displayed.
- Record the Route Activation Close Seal.
- Report all Close Seals to the Dispatcher(s).
|