| Error code |
Error |
| 60 |
Eprom factory initialize |
| 61 |
Drill |
| 62 |
Eprom housekeeping Write. |
| 63 |
One mode of the lock is corrupted. Try another and remove from service. If all modes give 63 Drill. If powers up 63 then Drill. |
| 64 |
Eprom Cust. Initialize |
| 65 |
Eprom Error List Read |
| 66 |
Eprom Error List Write |
| 67 |
One mode of the lock is corrupted. Try another mode and remove from service. If all modes give 67 drill. If powers up 67 then Drill. |
| 68 |
Eprom SMCS Write |
| 69 |
Eprom Bank User Read (Lock could not read the key to memory) |
| 6A |
Eprom Bank User Write (Lock could not write the opening into memory) |
| 6B |
Occurs with older model of lock. User key-different key closing lock than which opened the lock. Some are key specific some are mode specific. |
| 6C |
One mode of the lock is corrupted. If all modes give 6C drill. Try another mode once opened remove from service. If powers up 6C then Drill. |
| 6D |
One mode of the lock is corrupted. If all modes give 6C drill. Try another mode once opened remove from service. If powers up 6C then Drill. |
| 6E |
Eprom Delay-Data Write |
| 6F |
Eprom Factory Initialize Read |