Paxos - AS384 Management Suite Software

Updated Jul 7, 2025

– In Extended Mode of the locking system with the code format ID+PIN, the AS384 Management-
Suite Software allows the following for each lock:


– Additional master, time, mutation codes and net codes can be assigned.

– Through user profiles for each code (user) the standard authorizations of the corresponding code type can be extended or restricted, dual-mode groups defi ned, user-defined delays set, code ageing activated, and user profiles of a user profile group assigned.

– Code profile groups with the same access rights can be managed.

– In Extended Mode of the locking system with the code format “ID+PIN”, only the codes “00” (Master Code MA), “01” (Opening Code OCa) and “02” (Opening Code OCb) are pre-set. All other codes (“03”...“99”) can be defi ned individually with the AS384 Management-Suite Software as additional Opening Codes, additional Master Codes, Time Codes, Mutation Codes or Net Codes.