Configure the Input Signal on a 702 Non-Display Keypad in LA GARD 700 Series

Updated Mar 15, 2026

Question

How to configure the Input Signal on a 702 Non-Display Keypad in LA GARD 700 Series?

Answer

A configurable Input Signal is available on systems using 702, 703, 704, and 705 Keypad models. Using the Input Signal will require the installation of a Battery/Alarm Box (Item/Order # 704045). 

When used in a multi-lock system, Lock #1 monitors the state of this signal, and depending on how it is configured, it will perform one of the following functions when this signal is asserted: 

  • Ignored - Input Signal will have no effect on how the system operates
  • Remote Disabled/Lockout - When an open lock request is received for any lock, all requests to open will be blocked regardless of which target lock the user is attempting to open. This is the default setting.
  • Time Delay Override - Time Delay for all locks in the system is cancelled and any lock may be opened immediately by a user. If one or more locks were in either the Delay Period or the Confirmation Window, Time Delay is canceled, and the lock can be opened immediately by a user, with open privilege, providing the correct credentials
  • Dual User Override - Dual User requirements are ignored, allowing a single user to open a lock or access the menus

Follow these steps to configure the Input Signal on a 702 Non-Display Keypad: 

  1. Using the Keypad, input #16 + Master ID and Combination + Input Signal Mode (0 = Ignore, 1 = Remote Disabled/Lockout, 2 = Remote Time Delay Override, 3 = Remote Dual User Override) + (←).
  2. The Keypad will beep three times and flash a green LED once complete