Paxos - Enabling/disabling the Remote Lock Function

Updated Feb 21, 2026

Paxos - Enabling/disabling the Remote Lock Function

The Remote Lock function defines whether the locking system can be locked remotely using an external contact connected to the I/O-Box (default: Input 1).

  • When enabled, a signal on the configured input triggers a remote locking action.

  • When disabled, remote locking inputs have no effect.

  • By default, Remote Lock is disabled at delivery.

  • In Extended Mode, you can use the AS384 Management-Suite Software to assign the Remote Lock function to an input other than Input 1.

Configuration Rules and Behavior

  • If the system does not include an I/O-Box or IP-Box, this function has no operational effect, even if enabled.

  • You can enable or disable Remote Lock only in the settings for lock 1.
    The setting applies to the entire locking system.

  • By default, the Remote Lock input is monitored for sabotage.
    You can modify this monitoring behavior only using the AS384 Management-Suite Software.

  • The resistive circuit used for sabotage monitoring (for example, when connected to a hazard or alert system) is defined in the installation instructions.

Authorization: Master Code “MA1”
Requirement: System status Unlocked (door locks and door bolt open)

Steps to enable or disable the Remote Lock function

1. Wake up the display if necessary and access the menu.

Wake up display and access menu
Enter button
Confirm selection button

2. Select and confirm the menu option Settings.

Settings menu option
Enter button with down and up arrows
Confirm selection rotating button

3. Select and confirm Settings Lock 1.

Settings Lock 1 option
Enter button with down and up arrows
Confirm selection rotating button

4. Enter and confirm Master Code of lock 1.

Enter Master Code
Enter button with numeric/alphabetic buttons
Confirm selection rotating button

5. If the function Remote Lock is disabled, select and confirm the menu option “Settings L1 Other”.

Settings Lock 1 option
Enter button with down and up arrows
Confirm selection rotating button

6. Select and confirm menu option:

  • Other L1 Remote Lock
  • Settings S1 Remote Lock
Other L1 and Settings L1 Locking mode
Enter button with down and up arrows
Confirm selection rotating button

7. Select and confirm desired setting.

  • On: Enable Remote Lock
  • Off : Disable Remote Lock
Disable Remote Lock
Enable Remote Lock
Enter button with down and up arrows
Confirm selection rotating button

The selected setting is stored.

The input unit returns to the menu option “Settings S1 Remote Lock”. You can now configure other settings or return to the standard mode display.

Setting saved confirmation screen Locking Mode