Each LA GARD safe lock can be reset to factory defaults. This function is particularly useful when switching out a piece of the overall System that has a different model number than the previous version. A lock reset can be done one of two ways:
- Master Reset via the Keypad (both Display and Non-Display versions)
- Mechanical Reset via the Reset Box (Item/Order # 704065).
When a lock is reset:
- The Master Combination is reverted to the default (1-2-3-4-5-6-7-8).
- All Managers and Standard Users are deleted.
- All System and lock settings will be reset to their default.
- All locks will be uninstalled and unpaired from any Keypad.
Two items will not be deleted:
- Audits.
- Open count.
Note: Reset operations via reset box or via Master code reset will result in
- UTC time in lock will not be reset unless power has been removed for a period of time.
- DST rules tables will be defaulted to be no adjustments for any time zones.
- Time Zone will be set to GMT.
- DST observed flag will be set to true.
|