Question

How to Reset LA GARD 700 Series Lock?

Answer

Each LA GARD safe lock can be reset to factory defaults. This function is particularly useful when switching out a piece of the overall System that has a different model number than the previous version. A lock reset can be done one of two ways:

  1. Master Reset via the Keypad (both Display and Non-Display versions)
  2. Mechanical Reset via the Reset Box (Item/Order # 704065).

When a lock is reset:

  • The Master Combination is reverted to the default (1-2-3-4-5-6-7-8).
  • All Managers and Standard Users are deleted.
  • All System and lock settings will be reset to their default.
  • All locks will be uninstalled and unpaired from any Keypad.

Two items will not be deleted:

  1. Audits.
  2. Open count.

Note: Reset operations via reset box or via Master code reset will result in

  • UTC time in lock will not be reset unless power has been removed for a period of time.
  • DST rules tables will be defaulted to be no adjustments for any time zones.
  • Time Zone will be set to GMT.
  • DST observed flag will be set to true.